Dalam proses pendinginan, desain kondensor adil
Dalam proses pendinginan, desain kondensor yang adil merupakan bagian penting dalam meningkatkan rasio efisiensi ener...
PENDINGIN INDUSTRI SEMI-HERMETIS
PETUNJUK MODEL UINHT
PARAMETER TEKNIS PENDINGIN UDARA
Parameter Model | BF-LSBF04 | BF-LSBF05 | BF-LSBF08 | BF-LSBF10 | BF-LSBF15 | BF-LSBF20 | BF-LSBF30 | BF-LSBF35 | BF-LSBF40 | BF-LSBF50 | BF-LSBF60 | BF-LSBF80 | |
Efek pendinginan Kw | 10.6 | 15.1 | 19.5 | 28.1 | 41.9 | 42.1 | 61.3 | 80.4 | 92.1 | 108.8 | 122.6 | 184.2 | |
Daya total Kw | 4.51 | 5.53 | 7.71 | 11.49 | 15.76 | 15.59 | 23.26 | 28.64 | 33.45 | 41.99 | 45.44 | 66.9 | |
Maks. berjalan saat ini A | 7.6 | 10.1 | 15 | 17.6 | 24.3 | 37 | 53 | 61 | 78 | 92 | 106 | 156 | |
Sumber Daya listrik | 3PH/380V/50HZ | ||||||||||||
Mode pelambatan zat pendingin | Katup ekspansi panas | ||||||||||||
Pendingin | R22 | ||||||||||||
Sirkuit pendingin | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 | |
Kompresor
| Gaya | Tipe piston semi tertutup | |||||||||||
Model | BFBZ4 15 jam | BFBZ5 18 jam | BFBZ8 27 jam | BFBZ10 36 jam | BFBZ15 54 jam | BFBV20 56 jam | BFBV30 84,5 jam | BFBW35 110.5Jam | BFBW40 126.8 jam | BFBW50 151.6 jam | BFBV30 84,5 jam | BFBW40 126.8 jam | |
Daya Kw | 4.15 | 5.03 | 6.81 | 10.29 | 14.2 | 14.03 | 20.92 | 26.24 | 31.05 | 38.39 | 41.84 | 62.1 | |
Kuantitas | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 | |
Kondensator
| Membentuk | Tipe sirip aluminium tabung tembaga | |||||||||||
Model | BF- NCH/0500 | BF- NCH/0500 | BF- NCH/1000 | BF- NCH/1000 | BF- NCH/1500 | BF- NCH/2000 | BF- NCH/3000 | BF- NCH/4000 | BF- NCH/4000 | BF- NCH/5000 | BF- HVDK500 | BF- HVDK750N | |
Kekuatan Kipas Kw | 0.36 | 0.36 | 0.90 | 0.9 | 1.2 | 1.56 | 2.5 | 2.40 | 2.40 | 3.12 | 2.22 | 2.96 | |
Pengiriman Kipas m³/jam | 6300 | 6300 | 12600 | 12600 | 16660 | 21000 | 31500 | 33320 | 33320 | 47000 | 45000 | 60000 | |
Evaporator | Membentuk | Penukar panas tipe shell dan tube dengan efisiensi tinggi | |||||||||||
Refrigeran Sekunder | Air, glikol | ||||||||||||
Suhu Masuk ℃ | 12 | ||||||||||||
Suhu Keluaran ℃ | 7 | ||||||||||||
Laju Aliran m³/jam | 2.4 | 3.0 | 3.6 | 5.4 | 8.1 | 8.5 | 12.1 | 15.1 | 18.1 | 21.2 | 24.2 | 36.2 | |
Spesifikasi pipa penghubung | 1-1/2" | 1-1/2" | 1-1/2" | 1-1/2" | 2" | 2" | 2" | 2-1/2" | 2-1/2" | 2-1/2" | 3" | 3" | |
Menjalankan mode kontrol | Sepenuhnya otomatis | ||||||||||||
Perangkat perlindungan keselamatan | Unit perakitan memiliki perlindungan terhadap beban berlebih, kompresor memiliki perlindungan terhadap panas berlebih. Tekanan tinggi dan rendah, perlindungan tekanan oli; perlindungan fase terbuka; perlindungan suhu air sangat rendah; perlindungan laju aliran. |
Perkataan:
Kondisi kerja unit perakitan di bawah efek dan daya pendinginan nominal: suhu kondensasi 50℃, suhu air masuk 12℃, suhu air keluar 7℃
PARAMETER TEKNIS CHILLER BERDINGIN AIR
Parameter Model | BF-LSB04 | BF-LSB05 | BF-LSB08 | BF-LSB10 | BF-LSB15 | BF-LSB20 | BF-LSB30 | BF-LSB35 | BF-LSB40 | BF-LSB50 | BF-LSB60 | BF-LSB100 | |
Efek pendinginan Kw | 11.2 | 15 | 21.6 | 29.3 | 43.2 | 47.9 | 69.5 | 89.8 | 102.8 | 122.8 | 139 | 245.6 | |
Daya total Kw | 3.58 | 4.48 | 6.07 | 9.11 | 12.11 | 12.34 | 18.16 | 22.82 | 26.99 | 33.18 | 36.32 | 66.36 | |
Maks. berjalan saat ini A | 7.6 | 10.1 | 15 | 17.6 | 24.3 | 37 | 53 | 61 | 78 | 92 | 106 | 184 | |
Sumber Daya listrik | 3PH/380V/50HZ | ||||||||||||
Mode pelambatan zat pendingin | Katup ekspansi panas | ||||||||||||
Pendingin | R22 | ||||||||||||
Sirkuit pendingin | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 | |
Kompresor | Gaya | Tipe piston semi tertutup | |||||||||||
Model | BFBZ4 15 jam | BFBZ5 18 jam | BFBZ8 27 jam | BFBZ10 36 jam | BFBZ15 54 jam | BFBV20 56 jam | BFBV30 84.5H | BFBW35 110,5 jam | BFBW40 126.8 jam | BFBW50 151.6 jam | BFBV30 84.5H | BFBW50 151.6 jam | |
Kuantitas | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 | |
Membentuk | Penukar panas tipe shell dan tube dengan efisiensi tinggi | ||||||||||||
Kondensator
| Suhu air masuk ℃ | 30 | |||||||||||
Suhu air keluar ℃ |
|
|
|
|
| 3 | 5 |
|
|
|
|
| |
Laju aliran air pendingin m³/jam | 3 | 3.8 | 5.4 | 7.2 | 10.8 | 12.1 | 17.1 | 22.3 | 25.6 | 30.2 | 34.2 | 60.4 | |
Spesifikasi pipa penghubung | 1-1/2" | 1-1/2" | 1-1/2" | 2" | 2" | 2" | 2-1/2" | 2-1/2" | 2-1/2" | 2-1/2" | 3" | 4" | |
Evaporator
| Membentuk | Penukar panas tipe shell dan tube dengan efisiensi tinggi | |||||||||||
Refrigeran Sekunder | Air, glikol | ||||||||||||
Suhu Masuk ℃ | 12 | ||||||||||||
Suhu Keluaran℃ | 7 | ||||||||||||
Laju Aliran m³/jam | 2.4 | 3.0 | 4.8 | 6.1 | 8.6 | 9.1 | 13.3 | 16.9 | 19.7 | 23.2 | 26.6 | 46.4 | |
Spesifikasi pipa penghubung | 1-1/2" | 1-1/2" | 1-1/2" | 1-1/2" | 2" | 2" | 2-1/2" | 2-1/2" | 3" | 3" | 3" | 4" | |
Menjalankan mode kontrol | Sepenuhnya otomatis | ||||||||||||
Perangkat perlindungan keselamatan | Unit perakitan memiliki perlindungan terhadap beban berlebih, kompresor memiliki perlindungan terhadap panas berlebih. Tekanan tinggi dan rendah, perlindungan tekanan oli; perlindungan fase terbuka; perlindungan suhu air sangat rendah; perlindungan laju aliran. |
Perkataan:
Kondisi kerja unit perakitan di bawah efek dan daya pendinginan nominal: suhu kondensasi 50℃, suhu air masuk 12℃, suhu air keluar 7℃
Jika Anda memiliki pertanyaan atau butuh bantuan, silakan hubungi kami secara langsung, kami akan memberi Anda bantuan dan layanan online tepat waktu.
Produsen peralatan pendingin profesional
Zhejiang Beifeng Peralatan Pendingin Co, Ltd. memiliki sejarah 35 tahun dalam pembuatan peralatan pendingin. Saat ini, perusahaan ini memiliki dua basis pemrosesan yang berlokasi di Shengzhou, Zhejiang, dengan bangunan produksi seluas 60.000 meter persegi. Perusahaan ini telah mendirikan tiga perusahaan penjualan di Shanghai, Beijing, dan Guangzhou, dengan kekuatan teknis yang kuat, peralatan canggih, varietas lengkap, dan kualitas yang stabil. Perusahaan ini memiliki pusat inspeksi berkualitas tinggi untuk mendeteksi indeks kinerja produk pendingin dan detektor kebocoran helium tipe vakum impor untuk kondensor dan evaporator. Perusahaan ini memiliki pengaruh besar dalam industri pendingin nasional dan menempati pasar yang besar, dengan distributor di semua kota besar; Perusahaan ini menikmati reputasi tinggi tidak hanya di pasar domestik, tetapi juga di pasar luar negeri, dan produknya diekspor ke Eropa, Asia Tenggara, Timur Tengah, Amerika Utara, Afrika, dll.
Dalam proses pendinginan, desain kondensor yang adil merupakan bagian penting dalam meningkatkan rasio efisiensi ener...
Dalam sistem pendingin AC industri, evaporator, kondensor, kompresor, dan katup throttle merupakan empat komponen pen...
Kondensor yang berbeda menurut kondensasi uap dapat dibagi menjadi tipe permukaan (disebut juga tipe partisi) ...
Pendingin udara dapat digunakan untuk pendinginan atau kondensasi, dan banyak digunakan dalam: pemurnian, kond...
Di musim panas, suhu gas buang kompresor relatif tinggi dan tangan tidak dapat menyentuhnya. Menurut ...