Dalam proses pendinginan, desain kondensor adil
Dalam proses pendinginan, desain kondensor yang adil merupakan bagian penting dalam meningkatkan rasio efisiensi ener...
SPESIFIKASI SERI KOMPRESOR & KPADADENSI UNIT TECUMSEH PERANCIS MERK BEIFENG
R22 TEKANAN KEMBALI SEDANG/TINGGI
Model kompresor | Daya Nominal (HP.) | Pendingin | Pemindahan (cm³) | Perangkat ekspansi | Aliran Udara (m³/jam) | Suhu Penguapan | Tegangan | |||||
-25℃ | -15℃ | -10℃ | 0℃ | 7.2℃ | 15℃ | |||||||
AEZ 3340EH | 1/3 | R22 | 7.55 | C | 800 | 256 | 444 | 548 | 788 | 988 | 1221 | 208-220V/1/50HZ |
AEZ4440EHR | 1/3 | R22 | 7.55 | CN | 800 | 256 | 444 | 548 | 788 | 988 | 1221 | 208-220V/1/50HZ |
AEZ 9440TMHR | 1/3 | R22 | 7.55 | CN | 800 | 294 | 444 | 548 | 788 | 988 | 1221 | 220-240V/1/50HZ |
CAE 9460TMHR | 1/2 | R22 | 11.3 | CN | 800 | 410 | 653 | 808 | 1161 | 1426 | 1739 | 208-220V/1/50HZ |
CAJ 9480TMH/HR | 5/8 | R22 | 15.2 | CN | 1130 | 576 | 946 | 1155 | 1632 | 2036 | 2509 | 208-220V/1/50HZ |
TAJ 9480TMH/HR | 5/8 | R22 | 15.2 | CN | 1130 | 576 | 946 | 1155 | 1632 | 2036 | 2509 | 400V/3/50Hz |
CAJ 9510TMH/HR | 1 | R22 | 18.3 | CN | 980 | 711 | 1126 | 1374 | 1941 | 2411 | 2987 | 208-220V/1/50HZ |
TAJ 9510TMH/HR | 1 | R22 | 18.3 | CN | 980 | 711 | 1126 | 1374 | 1941 | 2411 | 2987 | 400V/3/50HZ |
CAJ9513TMH/HR | 1-1/8 | R22 | 24.2 | CN | 980 | 806 | 1348 | 1666 | 2370 | 2899 | 3523 | 208-220V/1/50HZ |
TAJ9513TMH/HR | 1-1/8 | R22 | 24.2 | CN | 980 | 806 | 1348 | 1666 | 2370 | 2899 | 3523 | 400V/3/50HZ |
CAJ 4517EHR | 1-1/4 | R22 | 25.95 | CN | 2200 | 1072 | 1692 | 2071 | 2978 | 3741 | 4681 | 208-220V/1/50HZ |
TAJ 4517TH/HR | 1-1/4 | R22 | 25.95 | CN | 2200 | 1072 | 1692 | 2071 | 2978 | 3741 | 4681 | 400V/3/50Hz |
CAJ 4519TH/HR | 1-3/4 | R22 | 34.45 | CN | 2250 | 1250 | 2144 | 2642 | 3767 | 4669 | 5739 | 208-220V/1/50HZ |
TAJ 4519TH/HR | 1-3/4 | R22 | 34.45 | CN | 2250 | 1250 | 2144 | 2642 | 3767 | 4669 | 5739 | 400V/3/50HZ |
FH 4522FH/HR | 2 | R22 | 40.8 | CN | 2250 | 1348 | 2257 | 2794 | 4028 | 5053 | 6297 | 208-220V/1/50HZ |
TFH 4522FH/HR | 2 | R22 | 40.8 | CN | 2250 | 1348 | 2257 | 2794 | 4028 | 5053 | 6297 | 400V/3/50HZ |
FH 4524FH/HR | 2 | R22 | 43.9 | CN | 2250 | 1282 | 2314 | 2910 | 4200 | 5322 | 6592 | 208-220V/1/50HZ |
TFH 4524FH/HR | 2 | R22 | 43.9 | ON | 2250 | 1282 | 2314 | 2910 | 4200 | 5322 | 6592 | 400V/3/50Hz |
FH 4531FH/HR | 2-3/4 | R22 | 58.1 | CN | 4800 | 1669 | 3611 | 4360 | 6163 | 7597 | 9277 | 208-220V/1/50HZ |
TFH 4531FH/HR | 2-3/4 | R22 | 58.1 | CN | 4800 | 1669 | 3611 | 4360 | 6163 | 7597 | 9277 | 400V/3/50HZ |
TFH 4540FH/HR | 3-1/2 | R22 | 74.25 | CN | 4600 | 1890 | 4157 | 5137 | 7438 | 9194 | 11300 | 400V/3/50Hz |
TAG 4546THR | 4 | R22 | 90.2 | CN | 7000 | 2347 | 4486 | 5569 | 8483 | 11244 | 14507 | 400V/3/50HZ |
TAG 4553THR | 4-1/2 | R22 | 10.7 | CN | 7000 | 3058 | 5360 | 6635 | 9745 | 12467 | 15797 | 400V/3/50HZ |
TAG 4561THR | 5 | R22 | 112.5 | CN | 6600 | 3218 | 5954 | 7607 | 11447 | 14317 | 17813 | 400V/3/50Hz |
TAG 4568THR | 6 | R22 | 124.4 | CN | 6000 | 3320 | 6579 | 8566 | 12759 | 16221 | 20116 | 400V/3/50HZ |
TAG 4573THR | 6-1/2 | R22 | 134.8 | CN | 6000 | 4613 | 7033 | 8739 | 12634 | 15589 | 19298 | 400V/3/50HZ |
TAG 4590THR | 7-1/2 | R22 | 180.4 | CN | 11500 | 4700 | 8309 | 10574 | 15628 | 19486 | 23990 | 400V/3/50Hz |
TAG4610THR | 9 | R22 | 201.7 | CN | 11500 | 5103 | 9354 | 12058 | 17926 | 22340 | 27393 | 400V/3/50HZ |
TAG 4612THR | 10 | R22 | 225 | CN | 11000 | 6604 | 11749 | 14841 | 22107 | 27561 | 34072 | 400V/3/50HZ |
TAG4614THR | 12 | R22 | 269.6 | CN | 10500 | 7104 | 12055 | 15443 | 23590 | 29775 | 37160 | 400V/3/50Hz |
Data kinerja berdasarkan: 50Hz
Suhu Sekitar: 32℃
R134A TEKANAN KEMBALI SEDANG TINGGI
Model kompresor | Daya Nominal (HP.) | Pendingin | Pemindahan (cm³) | Perangkat ekspansi | Aliran udara (m³/jam) | Suhu Penguapan | Tegangan | |||||
-25℃ | -15℃ | -10℃ | 0℃ | 7.2℃ | 15℃ | |||||||
AEZ 4430YHR | 1/4 | R134A | 8.85 | CN | 410 | 162 | 311 | 393 | 604 | 778 | 982 | 208-220V/1/50HZ |
AEZ 3440YH | 1/3 | R134A | 12.05 | C | 800 | 228 | 410 | 519 | 768 | 969 | 1212 | 220-240V/1/50HZ |
CAE 4440YHR | 1/3 | R134A | 12.05 | CN | 800 | 228 | 410 | 519 | 768 | 969 | 1212 | 208-220V/1/50HZ |
AE 3440YH | 1/3 | R134A | 12.05 | C | 800 | 241 | 433 | 553 | 841 | 1081 | 1375 | 220-240V/1/50HZ |
CAE 4440YHHR | 1/3 | R134A | 12.05 | CN | 800 | 241 | 433 | 553 | 841 | 1081 | 1375 | 220-240V/1/50HZ |
CAE 4448YHR | 3/7 | R134A | 14.15 | CN | 800 | 248 | 486 | 627 | 937 | 1186 | 1482 | 208-220V/1/50HZ |
CAE 4456YHR | 16/7 | R134A | 16 | CN | 980 | 298 | 538 | 689 | 1034 | 1319 | 1669 | 208-220V/1/50HZ |
CAJ 4461YH/HR | 1/2 | R134A | 18.3 | CN | 980 | 339 | 620 | 782 | 1156 | 1475 | 1843 | 208-220V/1/50HZ |
TAJ 4461YH/HR | 1/2 | R134A | 18.3 | CN | 980 | 339 | 620 | 782 | 1156 | 1475 | 1843 | 400V/3/50HZ |
CAJ 4476YH/HR | 5/8 | R134A | 21.75 | CN | 1130 | 447 | 750 | 956 | 1446 | 1867 | 2393 | 220-240V/1/50HZ |
CAJ 4492YH/HR | 3/4 | R134A | 25.95 | CN | 980 | 494 | 925 | 1179 | 1742 | 2229 | 2776 | 208-220V/1/50HZ |
TAJ 4492YH/HR | 3/4 | R134A | 25.95 | CN | 980 | 494 | 925 | 1179 | 1742 | 2229 | 2776 | 400V/3/50HZ |
CAJ 4511YH/HR | 1 | R134A | 32.7 | CN | 980 | 803 | 1216 | 1478 | 2138 | 2687 | 3370 | 208-220V/1/50Hz |
TAJ 4511YH/HR | 1 | R134A | 32.7 | CN | 980 | 803 | 1216 | 1478 | 2138 | 2687 | 3370 | 208-220V/1/50HZ |
FH 4518YH/HR | 1-1/2 | R134A | 53.2 | CN | 2250 | 1163 | 1791 | 2250 | 3463 | 4488 | 5848 | 208-220V/1/50Hz |
TFH 4518YH/HR | 1-1/2 | R134A | 53.2 | CN | 2250 | 1163 | 1791 | 2250 | 3463 | 4488 | 5848 | 400V/3/50HZ |
FH 4525YH/HR | 2 | R134A | 74.25 | CN | 2250 | 1147 | 2128 | 2759 | 4154 | 5424 | 6945 | 208-220V/1/50HZ |
TFH 4525YH/HR | 2 | R134A | 74.25 | CN | 2250 | 1147 | 2128 | 2759 | 4154 | 5424 | 6945 | 400V/3/50HZ |
TAG 4528YH | 2-1/2 | R134A | 90.2 | CN | 3540 | 978 | 2302 | 3132 | 5062 | 6687 | 8697 | 400V/3/50HZ |
TAG 4534YHR | 3 | R134A | 100.7 | CN | 4800 | 1336 | 2818 | 3760 | 5977 | 7859 | 10184 | 400V/3/50HZ |
TAG 4537YHR | 3-1/4 | R134A | 112.5 | CN | 4500 | 1573 | 3258 | 4304 | 6698 | 8690 | 11133 | 400V/3/50HZ |
TAG 4543YHR | 3-1/2 | R134A | 124.4 | CN | 4500 | 1737 | 3493 | 4638 | 7314 | 9601 | 12443 | 400V/3/50HZ |
Data kinerja berdasarkan: 50Hz
Suhu Sekitar: 32℃
R404A KOMPRESOR TEKANAN KEMBALI SEDANG/TINGGI
Model kompresor | Daya Nominal (HP.) | Pendingin | Pemindahan (cm³) | Perangkat ekspansi | Aliran Udara (m³/jam) | Suhu Penguapan | Tegangan | |||||
-25℃ | -15℃ | -10℃ | 0℃ | 7.2℃ | 15℃ | |||||||
AEZ 3440ZH | 1/3 | R404A | 7.55 | C | 800 |
| 448 | 552 | 783 | 970 | 1049 | 208-220V/1/50HZ |
AEZ 4440ZHR | 1/3 | R404A | 7.55 | CN | 800 |
| 448 | 552 | 783 | 970 | 1049 | 208-220V/1/50HZ |
AEZ 9440ZMHR | 1/3 | R404A | 7.55 | CN | 800 | 262 | 448 | 552 | 783 | 970 | 1049 | 220-240V/1/50HZ |
CAE 9460ZMHR | 1/2 | R404A | 11.3 | CN | 980 | 394 | 659 | 803 | 1117 | 1368 | 1472 | 208-220V/1/50HZ |
CAE 9470ZMHR | 16/9 | R404A | 13.3 | CN | 1130 | 520 | 847 | 1030 | 1441 | 1775 | 1915 | 208-220V/1/50HZ |
CAJ 9480ZMH/HR | 5/8 | R404A | 15.2 | CN | 1130 | 619 | 975 | 1176 | 1624 | 1992 | 2146 | 208-220V/1/50HZ |
TAJ 9480ZMH/HR | 5/8 | R404A | 15.2 | CN | 1130 | 619 | 975 | 1176 | 1624 | 1992 | 2146 | 400V/3/50HZ |
CAJ 9510ZMHR | 1 | R404A | 18.3 | CN | 980 | 773 | 1183 | 1427 | 1973 | 2398 | 2584 | 208-220V/1/50HZ |
TAJ 9510ZMHR | 1 | R404A | 18.3 | CN | 980 | 773 | 1183 | 1427 | 1973 | 2398 | 2584 | 400V/3/50HZ |
CAJ 9513ZMHR | 1-1/8 | R404A | 24.2 | CN | 980 | 861 | 1417 | 1718 | 2365 | 2869 | 3079 | 208-220V/1/50HZ |
TAJ 9513ZMHR | 1-1/8 | R404A | 24.2 | CN | 980 | 861 | 1417 | 1718 | 2365 | 2869 | 3079 | 400V/3/50HZ |
CAJ4517ZHR | 1-1/4 | R404A | 25.95 | CN | 2200 |
| 1757 | 2134 | 3029 | 3677 | 3960 | 208-220V/1/50HZ |
TAJ4517ZHR | 1-1/4 | R404A | 25.95 | CN | 2200 |
| 1757 | 2134 | 3029 | 3677 | 3960 | 400V/3/50HZ |
CAJ 4519ZHR | 1-3/4 | R404A | 34.45 | CN | 2250 |
| 2282 | 2731 | 3803 | 4643 | 5008 | 208-220V/1/50HZ |
TAJ 4519ZHR | 1-3/4 | R404A | 34.45 | CN | 2250 |
| 2282 | 2731 | 3803 | 4643 | 5008 | 400V/3/50HZ |
FH 4522ZHR | 2 | R404A | 40.8 | CN | 2250 |
| 2142 | 2664 | 3787 | 4676 | 5041 | 208-220V/1/50HZ |
TFH 4522ZHR | 2 | R404A | 40.8 | CN | 2250 |
| 2142 | 2664 | 3787 | 4676 | 5041 | 400V/3/50HZ |
FH 4524ZHR | 2 | R404A | 43.9 | CN | 2480 |
| 2397 | 2951 | 4160 | 5127 | 5529 | 208-220V/1/50HZ |
TFH 4524ZHR | 2 | R404A | 43.9 | CN | 2480 |
| 2397 | 2951 | 4160 | 5127 | 5529 | 400V/3/50HZ |
FH 4531ZHRE | 2-3/4 | R404A | 58.1 | CN | 4800 |
| 3416 | 4233 | 5990 | 7372 | 7939 | 208-220V/1/50HZ |
TFH 4531ZHR | 2-3/4 | R404A | 58.1 | CN | 4800 |
| 3416 | 4233 | 5990 | 7372 | 7939 | 400V/3/50HZ |
FH 4540ZHR | 3-1/2 | R404A | 74.25 | CN | 4800 |
| 4108 | 5016 | 7010 | 8609 | 9274 | 208-220V/1/50HZ |
TFH 4540ZHR | 3-1/2 | R404A | 74.25 | CN | 4800 |
| 4108 | 5016 | 7010 | 8609 | 9274 | 400V/3/50HZ |
FHD 4548ZHR | 4 | R404A | 87.8 | CN | 7000 |
| 4756 | 6237 | 9094 | 11059 | 11808 | 208-220V/1/50HZ |
TFHD 4548ZHR | 4 | R404A | 87.8 | CN | 7000 |
| 4756 | 6237 | 9094 | 11059 | 11808 | 400V/3/50HZ |
FHD 4562ZHR | 5 | R404A | 116.2 | CN | 6000 |
| 6673 | 8438 | 11749 | 13947 | 14767 | 208-220V/1/50HZ |
TFHD 4562ZHR | 5 | R404A | 116.2 | CN | 6000 |
| 6673 | 8438 | 11749 | 13947 | 14767 | 400V/3/50HZ |
TAG 4546ZHR | 4 | R404A | 90.2 | CN | 7000 |
| 4757 | 6013 | 8878 | 11256 | 12262 | 400V/3/50HZ |
TAG 4553ZHR | 4-1/2 | R404A | 100.7 | CN | 7000 |
| 5085 | 6357 | 9338 | 11769 | 12815 | 400V/3/50HZ |
TAG 4561ZHR | 5 | R404A | 112.5 | CN | 6600 |
| 5818 | 7351 | 10883 | 13766 | 14882 | 400V/3/50HZ |
TAG 4568ZHR | 6 | R404A | 124.4 | CN | 6000 |
| 6631 | 8506 | 12540 | 15550 | 16790 | 400V/3/50HZ |
TAG 4573ZHR | 6-1/2 | R404A | 134.8 | CN | 6000 |
| 7182 | 8881 | 12698 | 15853 | 17178 | 400V/3/50HZ |
TAG 4590ZHR | 7-1/2 | R404A | 180.4 | CN | 11500 |
| 8968 | 11266 | 16265 | 20237 | 21877 | 400V/3/50HZ |
TAG 461OZHR | 9 | R404A | 201.4 | CN | 11000 |
| 9796 | 12380 | 18172 | 22924 | 24918 | 400V/3/50HZ |
TAG 4612ZHR | 10 | R404A | 225 | CN | 11000 |
| 12015 | 14846 | 20947 | 25768 | 27754 | 400V/3/50HZ |
TAG 4614ZHR | 12 | R404A | 248.8 | CN | 10500 |
| 14074 | 17529 | 24416 | 29417 | 31386 | 400V/3/50HZ |
Data kinerja berdasarkan: 50Hz
Suhu Sekitar: 32℃
Jika Anda memiliki pertanyaan atau butuh bantuan, silakan hubungi kami secara langsung, kami akan memberi Anda bantuan dan layanan online tepat waktu.
Produsen peralatan pendingin profesional
Zhejiang Beifeng Peralatan Pendingin Co, Ltd. memiliki sejarah 35 tahun dalam pembuatan peralatan pendingin. Saat ini, perusahaan ini memiliki dua basis pemrosesan yang berlokasi di Shengzhou, Zhejiang, dengan bangunan produksi seluas 60.000 meter persegi. Perusahaan ini telah mendirikan tiga perusahaan penjualan di Shanghai, Beijing, dan Guangzhou, dengan kekuatan teknis yang kuat, peralatan canggih, varietas lengkap, dan kualitas yang stabil. Perusahaan ini memiliki pusat inspeksi berkualitas tinggi untuk mendeteksi indeks kinerja produk pendingin dan detektor kebocoran helium tipe vakum impor untuk kondensor dan evaporator. Perusahaan ini memiliki pengaruh besar dalam industri pendingin nasional dan menempati pasar yang besar, dengan distributor di semua kota besar; Perusahaan ini menikmati reputasi tinggi tidak hanya di pasar domestik, tetapi juga di pasar luar negeri, dan produknya diekspor ke Eropa, Asia Tenggara, Timur Tengah, Amerika Utara, Afrika, dll.
Dalam proses pendinginan, desain kondensor yang adil merupakan bagian penting dalam meningkatkan rasio efisiensi ener...
Dalam sistem pendingin AC industri, evaporator, kondensor, kompresor, dan katup throttle merupakan empat komponen pen...
Kondensor yang berbeda menurut kondensasi uap dapat dibagi menjadi tipe permukaan (disebut juga tipe partisi) ...
Pendingin udara dapat digunakan untuk pendinginan atau kondensasi, dan banyak digunakan dalam: pemurnian, kond...
Di musim panas, suhu gas buang kompresor relatif tinggi dan tangan tidak dapat menyentuhnya. Menurut ...